Gas Flow Meter based on the Laminar Flow Measuring Principle
In combination with differential pressure sensors for various, demanding applications, e. g. AKF-Flow-Measurement, Characterization of Fans and many more.
Advantages:
High Accuracy, very low Pressure Drop, low Flow Rates, high Dynamic, wide Temperature Range, small Size, no moving Parts, customer-specific calibration and ranges for each application, bidirectional Flow Measurement.
Flow Range: 0.03 to 1 200 l/min, other Ranges on Request (and any Range in between), Forward and Reverse Flow Measurement
Fluids: Air and other Gases, Fuel Vapor and many more
Linearity: typ. ≤ ± 0,5 % with Electronic Devices
Pressure Range: 800 to 1 200 mbar absolute pressure
Pressure Drop: ≤ 1 to 2 mbar differential pressure at Full Scale Flow Rate
Gas Temperature Range: -20 to +80 °C
Response Time: high dynamic for rapid flow rate changes (up to 1 kHz)
Output Signals:
Power Supply:
Flow Range: 0.027 to 0.55 l/min
Flow Range: 0.045 to 0.9 l/min
Flow Range: 0.12 to 2.4 l/min
Flow Range: 0.3 to 6 l/min
Flow Range: 0.75 to 15 l/min
Flow Range: 3 to 60 l/min
Flow Range: 7.5 to 150 l/min
Flow Range: 20 to 400 l/min
Flow Range: 33 to 600 l/min
Flow Range: 62.5 to 1 250 l/min