Measuring range:
(-1) 0 to 0,01 bar ... 0 to 1000 bar
We cover all the intervening measurement ranges.
Pressure type:
relative and absolute pressure
Output signal:
4 to 20 mA (2-lead set)
Supply voltage V (DC):
9 to 32 VDC unregulated
Basic accuracy
(non-linearity and repeatability):
≤± 0,05% of measuring range
Temperature range:
-40 to +85°C
Compensated: -10 to +80°C
Option: -40 to +85°C
Housing diameter:
Ø 22 mm